This document forms part of our Terms & Conditions. Back to Terms & Conditions
1. Our Estimates and the Standards We Follow
1.1 Before you sign a contract, we give you in writing an estimate of how each system we propose is likely to perform, and of its running costs and savings. We prepare each estimate using the method set out in the MCS standard for that technology, as listed in the Schedule, and in line with sections 5.3 and 5.4 of the Renewable Energy Consumer Code (RECC). Where MCS has published more than one version of a standard, we use the version that applies to our MCS certification (NAP32670) on the date of your quotation, and your quotation says which.
1.2 Each estimate is specific to your property. It uses the details we have recorded about your home, your energy use and the equipment we propose. Every assumption we make is set out in the estimate, with its source and date.
1.3 The performance of renewable energy systems can't be predicted with certainty. Our estimates are given as guidance and are not a guarantee of performance. Your quotation includes, word for word, the statements MCS requires us to give you with each estimate.
1.4 Nothing in this section limits your legal rights. In particular, we remain responsible if an estimate was not prepared with reasonable care and skill, did not follow the method described here, used information that was ours to get right and was wrong, or misled you.
1.5 We keep the calculations behind your estimates, and the information we relied on, for 10 years after installation, as RECC requires. You can ask us for a copy at any time.
1.6 We are a member of the Renewable Energy Consumer Code, member number 00068045, and MCS certified, number NAP32670.
2. Solar PV: How Much Electricity Your Panels Will Generate
2.1 We estimate the electricity your system will generate in its first year using the standard MCS formula:
where:
- kWp is the size of the system: the total of the rated output (Wp at standard test conditions) on the data plate of every panel installed;
- Kk is the expected output per kWp for your location, roof pitch and roof direction, taken from the MCS tables for your postcode zone (the same zones as SAP). MCS takes these figures from the European Commission Joint Research Centre's PVGIS solar data and multiplies them by 0.8 to allow for system losses;
- SF is the shade factor: 1.00 where there is a clear horizon and no shading, and less than 1.00 where shading will reduce output.
2.2 We measure the roof pitch (to the nearest 1°) and its direction from due south (to the nearest 5°) at our survey, or from plans, aerial photographs and roof data.
2.3 Where shading is present, we work out the shade factor using the MCS sun-path method: we draw the horizon as seen from the panels looking due south onto the MCS sun-path chart. Each of its 84 segments that the horizon touches or covers reduces output by 1%. For objects within 10 metres of the panels, such as chimneys, vent pipes, dormers and aerials, we add a shade circle as the method requires. We give you the sun-path chart we used. MCS states that this method is expected to give results within 10% of the actual annual output for most systems, but we cannot guarantee this.
2.4 Where we fit optimisers or other panel-level electronics, the MCS method does not count any benefit from them. Where we show you their effect, we show it separately and say how we calculated it.
2.5 If we give you an estimate before our technical survey, using measurements taken remotely, we will tell you. Actual performance may be significantly lower or higher than that estimate if the installed system differs from the estimated values. The estimate in your quotation is based on our survey (clause 6.1).
2.6 The estimate is for the first year of generation. Output varies from year to year with the weather. Panel output also falls slowly with age, at the rates stated by the panel manufacturer, which we give you in your estimate.
3. How Much of That Electricity You Will Use, With or Without a Battery
3.1 Self-consumption is the part of the electricity your panels generate that is used in your home rather than exported to the grid. We estimate it using the MCS lookup tables (MGD 003, or section 5 of MCS 032:2025 under MCS:2025). The tables use four inputs, which we state in your estimate:
- your annual electricity use, taken from your bills or meter readings where we have them (on a day/night meter, your day units plus 10% of your night units, as the MCS method requires), or otherwise estimated as the MCS method sets out;
- your occupancy pattern: home all day, in half the day, or out all day;
- the system's estimated annual generation from clause 2; and
- where a battery is included, its usable storage capacity.
3.2 We give self-consumption in kWh and as a percentage of generation, both without and with any battery. We also give your grid independence: the share of your home's electricity that the system supplies. MCS caps self-consumption at 95% of generation and grid independence at 90% of your use, regardless of the size of the batteries you ask us to quote for.
3.3 The MCS figure is the average for homes with the same occupancy pattern, electricity use and generation in the MCS modelling. It is not a prediction for your household: your actual self-consumption will depend on how and when you use electricity, and will vary from year to year. The MCS figure is the one to use when comparing quotes.
3.4 The MCS figure does not include electricity used by electric vehicle charging, heat pumps, electric heating or immersion diverters. Where these will add to your self-consumption, we show the extra amount separately and say how we worked it out.
3.5 We may also give you a second estimate from our own design software. It simulates a year in 10-minute steps using the sun on each roof, your household's pattern of use and any battery charging and discharging, scaled so the year's generation matches the MCS figure. We always show it separately from, and after, the MCS figure, and we tell you if it is significantly higher.
3.6 Our MCS certification covers the installation of battery storage to MIS 3012 (Classes 1, 2 and 3), so batteries we install are covered by MCS as well as the panels.
3.7 For each battery, your quotation also gives the information MCS requires (MIS 3012, or section 6.3 of MCS 032:2025), including its usable capacity, round-trip efficiency, warranties and their limits, whether it can supply power during a power cut, whether it can respond to time-of-use tariffs, and end-of-life recycling. Our estimate does not include savings from charging the battery on a cheaper night-time rate, unless we have agreed to estimate them on your own tariff.
4. Heat Pumps: Energy Use and Running Costs
4.1 We estimate a heat pump's electricity use using MCS 031 a) for heat pumps that heat water for radiators or underfloor heating, or MCS 031 b) for air-to-air heat pumps. We design the system to MIS 3005-D.
4.2 Your home’s annual heat demand for space heating and hot water is taken from a valid Energy Performance Certificate (EPC), which uses calculation software called RdSAP10. Where there is no valid EPC, or the EPC is out of date, we use our own RdSAP10 calculation from your Home Assessment. Once your assessment is complete we lodge it as an EPC on the government EPC register, whether or not your home already has one (see clause 7.2 of our Terms and Conditions). The RdSAP10 calculation relies on information that may have to be assumed, such as insulation levels, so it can differ from your home’s actual demand.
4.3 Before installation we carry out a room-by-room heat loss calculation to BS EN 12831-1:2017, as MIS 3005-D requires. The heat pump size and the estimate in your quotation may change as a result, and we will give you the revised figures in writing (see clause 6).
4.4 For a heat pump heating water for radiators or underfloor heating, we divide the space heating demand by the seasonal performance factor (SPF) from the MCS tables. The SPF depends on your home's heat loss per square metre, the type of heat emitters and the flow temperature. MCS requires us to assume a flow temperature of 60°C unless a room-by-room heat loss calculation has been done. Hot water uses the MCS performance factor of 1.9 (2.2 for ground source). We add any electricity an immersion heater will use to keep the hot water cylinder free of bacteria. For air-to-air heat pumps, MCS 031 b) sets the performance figure to use.
4.5 We give the heat pump's electricity use as a range, from 10% below to 10% above the calculated figure, as MCS requires. We convert this to a running cost using the electricity price in clause 5.2.
4.6 Heating energy use is hard to predict. It depends on the weather, the temperatures you set, how much hot water you use, when you are at home and how much you ventilate. MCS advises that an accuracy of plus or minus 25 to 30% would not be unreasonable in many cases, and that it can be exceeded. Please take this into account if your decision rests mainly on cost or payback.
4.7 Where we compare a heat pump's running cost with your current heating, we use the same heat demand, the efficiency of your existing heating as recorded in the EPC, and your current fuel price set as in clause 5.2. MCS performance estimates for different heating technologies use different methods and are not directly comparable with each other. Where we use your EPC heating efficiency before we carry out your Home Assessment, this will be based on existing online data from the EPC register, which may include any updated information you tell us. If you do not have an existing EPC, we will ask you questions about your home to estimate this information, which makes the results less accurate. Once we have completed your Home Assessment, we have much more accurate and up to date information and this will be provided to you with your quote and final design.
5. Savings, Export Income and Payback
5.1 Any estimate of savings or payback we give you is in writing and based on your actual energy use and pattern of use, as RECC requires. We state every assumption, with its source and date.
5.2 For the price you pay for electricity, we use, in this order:
- the unit rate on your most recent electricity bill, once we have checked it;
- if we have no bill, the unit rate recorded by our assessor at your Home Assessment, which we will say we have not checked against a bill;
- otherwise, the Ofgem energy price cap unit rate for your region, paying by Direct Debit, for the cap period current on the date of your quotation.
If you have a day/night tariff, we use the day rate, because panels generate most in the daytime. Where we compare heating costs (clause 4.7), we price your current fuel the same way, using the Ofgem price cap rate for that fuel where it has one. For fuels the price cap does not cover (heating oil, LPG, solid fuel, wood and heat networks), and for off-peak electricity tariffs, we use the fuel prices BRE publishes for the government in the Product Characteristics Database (www.ncm-pcdb.org.uk), which are used for the running costs on Energy Performance Certificates.
5.3 Standing charges do not change when you install solar panels or a battery, so they are not included in those savings. Where a heat pump replaces your gas boiler, we assume you stop using gas and have the gas meter removed, so you no longer pay the gas standing charge; we show that saving as its own line, at the Ofgem price cap. If you keep a gas hob, cooker or fire, you will still pay the gas standing charge and your saving will be lower by that amount. The same applies to an LPG tank where a heat pump replaces an LPG boiler.
5.4 For electricity you export, we use the Smart Export Guarantee (SEG) rate stated in your estimate. Export rates are set by energy suppliers, are not regulated and vary between them. We also list the SEG tariffs we found on suppliers' websites, with the date we checked, but we cannot guarantee that these are accurate or up to date. If you choose a different tariff, your export income will be higher or lower in proportion.
5.5 Your estimated first-year saving from solar panels, with or without a battery, is:
- the electricity you use from the system instead of buying it (clause 3), multiplied by your electricity price (clause 5.2); plus
- the electricity you export, multiplied by the export rate (clause 5.4).
Where a battery is included, we use the MCS self-consumption figure for the panels and the battery together, and the energy lost in charging and discharging the battery is not counted as exported. The battery’s saving is the difference between that figure and the figure for the panels alone; it is never added on top of the panels’ saving.
We do not use the Energy Performance Certificate (EPC) calculation for solar or battery savings. The EPC method is made to rate homes, not to estimate a household’s bill. It assumes a standard household, not your own electricity use, and in working out the rating it values the electricity you export at the full price of standard-rate electricity, not at an export rate. It gives a different figure from the MCS method, which is the one we use for solar panels and batteries (MCS 001-1, clause 4.4.2 b).
5.6 We calculate payback as the price you pay, after any grant, divided by the savings year by year, until the savings add up to that price. We show the payback in two ways, side by side and with equal weight:
- with energy prices rising as set out in clause 5.7, and allowing for the panels’ output falling with age (clause 2.6); and
- at today’s prices, with no rise at all, allowing for the panels’ output falling with age.
We also give the simple payback: the price you pay divided by the first-year saving. Where your installation is fully funded, we do not show a payback.
5.7 For future energy prices, we assume each fuel’s unit price rises every year by the average yearly rise in that fuel’s price over the ten years from June 2016 to July 2026, in the fuel prices BRE publishes for the government in the Product Characteristics Database (www.ncm-pcdb.org.uk), which are used for the running costs on Energy Performance Certificates and are updated about every six months.
- For standard-rate electricity, that is 5.4% a year (15.44p per kWh in June 2016 to 26.34p per kWh in July 2026).
- Your estimate states the rate used for each fuel.
- The rise applies to the unit price only. We hold standing charges and the export rate at today’s figures, with no rise.
This is an assumption, not a forecast: energy prices can fall as well as rise, and have done both in recent years, so your actual saving and payback may be better or worse. On our website you can switch the price rise off to see every figure at today’s prices.
5.8 If you pay using finance, any payback period we give you is worked out on the total amount you will pay, including interest, not just the cash price. We will never tell you that your savings will cover, or pay for, your finance repayments: your repayments are fixed, while your savings are an estimate that can go up or down. The cost of your finance is set out in the lender's own documents, and the decision to borrow should not rest on our savings estimate.
5.9 These figures are to help you compare options. Please don't choose an energy tariff or switch supplier on the strength of them, and don't decide to install based only on financial benefits or on a particular energy price or tariff, as these can change.
6. Surveys, Changes to Your Estimate and Your Right to Cancel
6.1 We always carry out a technical site survey at your home before you sign. Any estimate we give you before the survey, for example from the EPC register or aerial images, is indicative only. The estimates in your quotation are based on our survey.
6.2 If, after you sign, the room-by-room heat loss calculation or the final design changes any estimate, we will give you the revised estimate in writing before the work goes ahead. If the change makes the estimate worse for you and was not requested by you, you may cancel the contract without penalty. This is in addition to your 14-day cancellation right.
6.3 If, after you sign, we find something our survey could not reasonably have shown that means the system cannot be installed, we will refund your deposit in full.
6.4 If you ask us to change the design, for example the number of panels or the battery size, we will give you a revised estimate in writing before the work goes ahead.
6.5 Your system's actual performance, running costs and savings will also depend on things we do not control. These include the weather, how and when you use energy, changes to your household, changes in energy prices and tariffs, the export rate your supplier pays, new shading (for example from trees or buildings), and how the system is operated and maintained.
6.6 If you think your system is performing significantly below its estimate, please contact us. We will check the system and the estimate. If we cannot resolve your concern, our complaints procedure explains how to refer it to RECC or MCS.
Schedule: Documents Referred To
We use the issue current on the date of your quotation; if MCS or RECC replaces a document, the replacement applies to quotations issued after its effective date. The "MCS:2025" documents apply once our certification moves to that version of the scheme.
| Document | Issue and date | Used for (clause) |
|---|---|---|
| Renewable Energy Consumer Code (RECC) | Version 9, 1 July 2026 | Performance estimates, savings and quotations (1, 5, 6) |
| RECC Bye-Laws | August 2026 | Definitions and Code membership (1) |
| MCS Customer Commitment | MCS:2025 2.0, Issue 1.1, 8 September 2026 | Realistic estimates before contract (1, 5.8) |
| MIS 3002, The Solar PV Standard (Installation) | Issue 6.0, 18 March 2026 | Solar PV generation estimate and required statements (2) |
| MGD 003, Solar PV Self-Consumption | Issue 2.0, 1 April 2022 | Self-consumption with and without a battery (3) |
| MGD 005, Solar PV Shade Evaluation Procedure | Issue 1.0, 16 September 2020 | Shade factor (2.3) |
| MIS 3012, Battery Storage Systems | Issue 1.0, 22 November 2021 | Battery information (3.6, 3.7) |
| MIS 3002:2025, Solar PV: Installation Standard | Issue 2.0, 18 March 2026 | Solar PV installation (MCS:2025) (2) |
| MCS 032:2025, Solar PV and Battery: Pre-Sale Information and System Performance Estimate Standard | Issue 1.0, 1 January 2025 | Generation, shade (Appendix A), self-consumption (section 5) and battery information (section 6.3) under MCS:2025 (2, 3) |
| MIS 3012:2025, Battery: Installation Standard | Issue 1.0, 1 January 2025 | Battery installation (MCS:2025) (3.6, 3.7) |
| MCS 031 a), Hydronic Heat Pump: Pre-Sale Information and Calculations | Issue 5.0, 5 December 2025 | Heat pump energy use and running costs (4) |
| MCS 031 a):2025, Hydronic Heat Pump: Pre-Sale Information and System Performance Estimate Standard | Issue 2.0, 5 December 2025 | As above, under MCS:2025 (4) |
| MCS 031 b), Air to Air Heat Pump: System Performance Estimate | Issue 1.0, 5 December 2025 | Air-to-air heat pump estimate (4) |
| MCS 031 b):2025, Air to Air Heat Pump: Pre-Sale Information and System Performance Estimate Standard | Issue 1.0, 5 December 2025 | As above, under MCS:2025 (4) |
| MIS 3005-D, The Heat Pump Design Standard | Issue 3.0, 5 December 2025 | Heat pump design and heat loss (4.1, 4.3) |
| MIS 3005-D:2025, Heat Pump: Design Standard | Issue 2.0, 5 December 2025 | As above, under MCS:2025 (4.1, 4.3) |
| BS EN 12831-1:2017, Energy performance of buildings: method for calculation of the design heat load | 2017 | Room-by-room heat loss (4.3) |
| Ofgem energy price cap | The cap period current on your quotation date | Electricity and fuel prices where we have no bill (5.2); the gas standing charge (5.3) |
| Product Characteristics Database (PCDB), fuel price tables 191 (current) and 199 (historical), BRE for the Department for Energy Security and Net Zero | The issue current on your quotation date; the ten-year rises use June 2016 and July 2026 | Prices for fuels without a price cap (5.2); future price rises (5.7) |
MCS standards are published at mcscertified.com and the Consumer Code at recc.org.uk. British Standards are sold by BSI. If you ask, we will tell you where to find any document listed here.